Small Panel Van Road & Standby
Introducing The Small Panel Van Unit
The L201 range of refrigeration systems from GAH offers various options for operators requiring temperature control during the delivery of chilled or frozen goods in small to medium suitably insulated panel vans and box bodies with single phase electric standby.
The stylish aerodynamic design utilises plastic covers for the condenser and the evaporator.
A vehicle engine driven compressor powers the units on truck drive. The new quieter GAH rotary compressors are utilised for standby.
An in-cab controller with digital display monitors and controls the temperature and defrosting whilst providing a constant load space temperature readout.
Features & Benefits
Chill models are easy to operate with off cycle defrost. Perfect for delivering chilled packaged goods.
Freeze models are easily set to the desired temperature. All functions are fully automatic. For applications below -20°C see Medium Panel Van.
Approximately 85 kg standby installed making this the lightest system in it's class.
A cubic metal single fan evaporator is supplied as standard.
A slim plastic single fan evaporator can be supplied at no additional cost.
With single phase hermetically sealed rotary standby
Whilst cooling the load space, moisture in the air collects on the evaporator coil. GAH chill units have an automatic, hourly off cycle defrost to keep the coils free of frost. GAH freeze units have hourly, automatic and fast reverse cycle defrost for closer temperature control which allows the unit to cool for more minutes per hour.
Technical Specification
Below are the standard options for this refrigeration system. If you require something different, please call GAH on 01394 421140 to discuss your requirements with an application specialist.
Type | Chilled | Frozen | Heat-Cool | Flexi | VLA |
---|---|---|---|---|---|
Road & Standby |
Applications & Compatabilities
Please note these guides are offered as an approximation only. For confirmation and a more detailed quotation, please contact one of our application specialists.
The L201C is a chill only system, the L201F is for frozen applications or chill applications where a full defrost is required. The choice can be affected by the product to be carried and the number of door openings per working day and the way the system is used. If in doubt, please talk to a GAH Applications specialist for clarification.
The following assumptions have been made:
- Ambient temperature 30°C
- Chilled ‘K’ Factor is 0.7 W/M²/°C
- Frozen ‘K’ Factor is 0.4 W/M²/°C
- Drop duration is 3-5 minutes
Small Panel Sized Vehicles (up to 4m³)
Chilled (0–3°C) up to 4 drops per hour
(30 in an 8 hour day)
Frozen (–18°C) up to 2-3 drops per hour
(20 drops in an 8 hour day)
Small Panel Sized Vehicles (5–8m³)
Chilled (0–3°C) up to 3 drops per hour
(24 drops in an 8 hour day)
Frozen (–18°C) up to 1 drops per hour
(8 in an 8 hour day)
Fresh Food
Frozen Food
Heat/Cool Applications